SolarEdge StorEdge SE7600A-USS Hybrid Inverter 7.6kW, -25 to +60°C

Product description

The StorEdge SE7600A-USS & SE3800A-USS hybrid grid tie inverter has the capability to use energy storage to enhance self-consumption of solar energy. This is useful when net-metering, or grid feed is not available, or not advantageous financially. This system uses DC coupling for both the solar and the connection to the battery system for greater overall efficiency. The system features export control, time-of-use shifting, maximized self-consumption, and peak shaving capabilities. These features can use any of the loads in the house, including those on the main service panel. Backup power is also available with the addition of the Auto-transformer. Backup power is only available to the loads connected to the backup critical loads panel. Backup power capacity is 5 kW. Switchover upon a power outage can take up to 2 seconds. The StorEdge inverter is compatible with certified high voltage battery systems.

Like SolarEdge inverters, they are designed to work exclusively with SolarEdge power optimizers for use with solar modules. Both the optimizer strings and battery system operate at a nominal 400 VDC. The inverter and optimizers have ground fault and arc fault protection, and automatically limit the DC voltage to 1 VDC per module, and the battery is disabled when the inverter is not connected to the grid, improving installer and firefighter safety.

When used for export control, time-of-use shifting, self-consumption, or peak shaving capabilities, the SE Electricity Meter is needed and comes with CT’s to be installed on the house AC lines. For backup power capability the SEAUTO-TX-5000 auto-transformer must be installed as well as a backup loads panel for the critical loads.

SKU SE7600A-USS2RNCB2 Categories , ,
Brand:SolarEdge

Description

General Information:

  • Product Line: StorEdge
  • Model ID: SE7600A-USS2RNCB2

Mechanical Data:

  • Technology: Hybrid Inverter
  • Dimensions: 37.00 x 12.50 x 7.20 inches
  • Weight: 58.50 lbs
  • Operating Temperature Range: -25 to +60°C
  • Cooling: Natural Convection and Internal Fan (User Replaceable)
  • Noise: < 50dBA
  • AC Output Conduit Size: 1″ / 14-6 AWG
  • AC Output (Backup): 0.75-1″ Knocknouts / 14-6 AWG
  • AC Input (Auto-Transformer): 0.75-1″ / 14-6 AWG
  • DC Input (PV) Conduit Size: 0.75″ / 14-8 AWG
  • DC Input (Battery) Conduit Size: 0.75″ / 16-10 AWG
  • Protection Rating: NEMA 3R
  • Certifications: UL1741, UL1699B, UL1998 , CSA 22.2
  • Grid Connection Standards: IEEE1547, Rule 21, Rule 14
  • Emissions: FCC Part 15 Class B
  • Supported Communication Interfaces: RS485 for Battery, RS485, Ethernet, ZigBee (Optional)
  • Battery Power Supply: Yes, 12V/53W
  • Revenue Grade Data, ANSI C12.1: Yes
  • AC Disconnect: Yes
  • Manual Inverter Bypass Switch: Yes
  • DC Voltage Rapid Shutdown (PV and Battery): Yes, According to NEC 2014 690.12
  • Auto-Transformer Thermal Protection: Yes
  • Supported Battery Types: LG Chem RESU10H
  • Number of Batteries per Inverter: 1 or 2
  • Continuous Power: 5000 Watts
  • Peak Power: 7000 Watts
  • Max. Input Current: 17.50 ADC
  • 2-Pole Disconnection: Yes
  • DC Fuses on Plus and Minus: 25 A (Field Replaceable)

Electrical Data:

  • Output – AC (Loads/Grid)
  • Nominal AC Power Output: 7600VA
  • Maximum AC Power Output: 8350VA
  • AC Output Voltage: Min: 211 VAC; Nominal: 240 VAC; Max: 264 VAC
  • AC Frequency: Min: 59.3Hz; Nominal: 60.0Hz; Max: 60.5Hz
  • Max. Continuous Output Current: 32 Amps
  • GFDI: 1 Amp
  • Utility Monitoring, Islanding Protection, Country Configurable Set Points: Yes
  • Charge Battery from AC (If Allowed): Yes
  • THD: < 3%
  • Power Factor with Rated Power: >0.99 (Configurable; 0.9 Leading to 0.9 Lagging)
  • Typical Nighttime Power Consumption: <5 Watts
  • Output – AC (Backup Power)
  • Rated AC Power Output: 5000 VA
  • Max AC Power Output – Surge: 7600 for 10 Sec VA
  • AC Output Voltage: Min: 211 VAC; Nominal: 240 VAC; Max: 264 VAC
  • AC Frequency: Min: 55 Hz; Nominal: 60 Hz; Max: 65 Hz
  • Maximum Continuous Output Current @240V: 21 Amps
  • Maximum Continuous Output Current per Phase @120V: 25 Amps
  • GFDI: 1 Amps
  • AC Circuit Breaker: Yes
  • THD: <5 %
  • Power Factor with Rated Power: 0.2 Leading to 0.2 Lagging
  • Automatic Switchover Time: < 2 Sec
  • Typical Nighttime Power Consumption: < 5 Watts
  • Transformer-Less, Ungrounded: Yes
  • Maximum Input Voltage: 500 VDC
  • Nominal DC Input Voltage: 400 VDC
  • Reverse-Polarity Protection: Yes
  • Ground-Fault Isolation Detection: 600kΩ Sensitivity
  • Maximum Inverter Efficiency: 98%
  • CEC Weighted Efficiency: 97.50%
  • Maximum DC Power (STC): 10250 Watts
  • Maximum Input Current: 23 ADC
  • 2-Pole Disconnection: Yes

Features:

  • Highlights – 5,000 W backup, 3,800 & 7,600 W grid-tie output options. Internal Arc Fault Circuit Interrupter (AFCI) for added safety per NEC 2011: 690.11. Inherently compliant with NEC 2014 690.12 rapid shutdown requirement. Built-in module-level and battery system monitoring. GSM Cellular Card with 5-year plan prewired and included. RS485 and Ethernet communications interface included. NEMA 3R outdoor rated. Inverter operating temperatures of -13 °F to +140 °F (-25 °C to +60 °C). Optional revenue grade monitoring.

Brand

SolarEdge

Downloads

SE7600A-U Installation
SE7600A-USS20NNB2 Specs
SolarEdge Warranty