Chilicon Modular Trunk Cable, AWG 10, 1.025mm (~40"), 60/72 Cell Portrait Modules, MTC-P

  • Chilicon Power inverters feature Integrated (DC isolated) Ground.
  • DC circuit is isolated and insulated from ground.
  • microinverters do not require a Grounding Electrode Conductor (GEC) connected between each microinverter.
  • Don’t need to attach a separate copper grounding conductor to each microinverter or worry about a continuous run to ground.
SKU SE-CP-IA-5 Categories ,

Description

Chilicon Power 1.025m Modular Trunk Cable Portrait MTC-P-10

The trunk cabling portion of a microinverter system is extremely important since it directly impacts labor costs at an installation site. The Chilicon modular trunk and branch cabling system incorporates industry standard 10 AWG VNTC tray cable with a UV and cut resistant outer jacket. Each ‘modular’ component of the 4 conductor cable plugs together right on the job site. For the first time, you can mix landscape and portrait mode PV module layouts side-by-side on the same string. In addition, the trunk cable is Self-Terminating. There is no longer a need to procure termination caps for the end of each microinverter string.

The trunk cable’s 10 AWG cabling enables the use of 30 A OCP devices (typically a 2 pole circuit breakers). This means that 20 Chilicon CP250e devices running 289W output can be wired on a single 30 A string in 240V split-phase mode, or 18 Chilicon CP250e devices running 277W output can be wired on a single 30A string in 208V three-phase mode.

Integrated Grounding

Electrical code requires two types of grounding conductors: the Grounding Electrode Conductor (GEC), which is used between the grounding electrode and the point where a normal current carrying conductor is intentionally bonded to ground and the Equipment Grounding Conductor (EGC), which grounds noncurrent-carrying metal parts of the system, such as the racking and module frames. Because Chilicon Power microinverters have DC integrated ground, they do not require a GEC. However, the electrical code still requires that exposed metal in the array be grounded (NEC 690.43 and 250.136(A)). This requirement is met for the microinverter because the ground conductor internal to the modular trunk cable acts as the EGC. It may be met for racking and modules with use of an EGC or WEEBs to provide bonding to this ground system.

Color Codes

  • Pin 1 – G: Green
  • Pin 2 – L1: Black
  • Pin 3 – N: White
  • Pin 4 – L2: Red